XLPE Insulated Electrical Cable For Rated Voltage 3.6/6kv~26/35kv

XLPE Insulated Electrical Cable For Rated Voltage 3.6/6kv~26/35kv
company Ventria Bioscience co.,ltd
Update2011-04-01
Original RegionChina
XLPE Insulated Electrical Cable For Rated Voltage 3.6/6kv~26/35kv
For XLPE insulated power cable,either chemical or physical method is employed to transform the molecular structure of PE from chain into three-dimensional network,i.e. thermoplastic PE is transformed into thermosetting XLPE.After cross-linking,the thermal and mechanical properties of PE have been greatly improved while tis excellent electrical property are still retained.
The maximun permissible operating temperature of the conductor of a XLPE insulated power cable is 90℃ which resistance is higher than that of PVC or PE insulated power cable.The cable has the advantage of simplicity in construction,lightness in weight,convenience in application besides its excellent electrical,thermal,mechanical and anti-chemical corrosion properties.It can also be laid with no limitation of level difference along the route.
Product Standard
The product is manufactured according to the standard of GB/T12706-2002 Eltruded solid dielectric power cables for rated voltages from 1kV(Um=1.2kV) to 35kV(Um=40.5kVor IEC,BS,DIN and ICEA upon request.
Applications
The product is suitable for use in power transmission and distribution lines with rated power frequency voltage 3.6kV~26kV/35kV.
Operating characteristics
Rated power-frequency voltage U0/U:3.6/6kV~26/35kV.
Max. Permissible continuous operating temperature of conductor:90℃.
Max. short-circurt temperature of conductor shall not exceed 250℃(5s maximum duration)
Thte ambient temperature under installation should not below 0℃.
The bending radius of a single-core cable should not less than 20 times of the cable diameter.
The bending radius of a three-core cable should not less than 15 times of the cable diameter.
Voltage designation
The rated voltage of the cable for a given application shall be suitable for the operating conditions in the system in which the cable is used,and is expressed in the form of U0/U(UM)kV. Where:
U0—The rated power-frequency voltage between conductor and earth or metallic screen,for which the cable designed;
U —The rated power-frequency voltage between conductors,for which the cable designed;
Um—The maximum value of the highest system voltage” for which the equipment may be used.
The values of U0 recommened for cable to be used in three-phase systems are listed below.
U
kV
Um
kV
U0*kV
System categories A and B
System categories C
6
7.2
3.6
6
10
12
6
8.7
15
17.5
8.7
12
20
24
12
18
30
36
18
35
40.5
21
26
System category A—This category comprises those systems in which any phase conductor that comes in contact with earth or an earth conductor, is disconnected from the system with in 1 min.System category B—This category comprises those system which,under fault conditions, are operated for a short time with one phase earthed.This period should not exceed 1h. For a longer period,not exceeding 8h on ant occasion,can be tolerated.The total duration of earth faults in any year should not exceed 125h.
System category C—This category comprises all systems which do not fall into categories A and B.
Type of cable
Type
Designation
Application
YJV
Copper conductor,XLPE insulated and PVC sheathed power cable
For laying indoors,in tunnel or cable trench,unable to bear external mechanical forces.single core cable in megnetic duct is not permissible.
YJLV
Aluminium conductor,XLPE insulated and PVC sheathed power cable
YJY
Copper conductor,XLPE insulated and PE sheathed power cable
YJLY
Aluminium conductor,XLPE insulated and PE sheathed power cable
YJV22
Copper conductor,XLPE insu